TROUBLESHOOTING GUIDE
 

Acella™ Chemically Competent Cells
Acella™ pLysS Chemically Competent Cells

OBSERVATION
POSSIBLE CAUSE
RECOMMENDATIONS

Transformation
efficiencies lower than
expected

There may be DNA impurities present. Ensure that the DNA does not contain any protein,
detergents or ethanol.
There may be too much DNA. Transformation efficiencies are calculated using
10pg pUC19. Transformation efficiencies will
decrease with increasing amounts of DNA;
however, total number of clones will increase with
the amount of DNA.
The cells may have been improperly
handled or stored.
dot Cells should be thawed in ice and used
immediately. Do not refreeze cells and do not
vigorously mix cells by vortexing. Cells must
be stored at -80°C to guarantee stability.
dot Transformation should be done according to
the recommended protocol to ensure the
guaranteed transformation efficiency.
You may be using a very
large plasmid.
Transformation efficiencies are calculated using
pUC19. Larger plasmids will result in lower
transformation efficiencies.
The ligation may have been inefficient. Double check the cloning strategy, enzymes and
concentrations of vector and insert. Set up a
control for each step of the cloning procedure.
You may have too little DNA in
your ligation mix.
Increase the amount of vector and/or insert in your
ligation.
You may have restriction enzymes or
phosphatase remaining
in your ligation mix.
Make sure that you inactivate or eliminate any
trace of restriction enzymes or phosphatase before
ligating your DNA.
You may have the wrong antibiotic
concentration.
Some plasmids with very low copy number require
lower antibiotic concentrations than standard high
copy number plasmids. Verify the antibiotic
concentration is optimal for your vector.
You may have diluted your
transformation too much.
After ligation, calculated transformation efficiencies
are usually much lower than transformation
efficiencies calculated with supercoiled DNA. You
may plate most of your transformations to ensure
that you get colonies and dilute the rest to ensure
that you obtain single colonies.
Top of PageTop of Page
OBSERVATION
POSSIBLE CAUSE
RECOMMENDATIONS

Satellite colonies

The antibiotic concentration
may be incorrect.
Check the antibiotic concentration added to the
plates.
The ampicillin may be degraded. Make sure that ampicillin was not added to the
medium when it was still too hot and that it was
properly stored. Use carbanicillin, an antibiotic
similar to ampicillin with improved stability. Check
that plates are not more than one month old or
have been stored above 4°C.
You may have too many
colonies in the plate.
Plate the transformation at a higher dilution.
You may have incubated
the plates too long.
Incubate the plates overnight (16-18 hours) at 37°C
or for 2-3 days at room temperature in the case of
temperature-sensitive plasmids.
Top of PageTop of Page
OBSERVATION
POSSIBLE CAUSE
RECOMMENDATIONS
Little or no protein
expression detected
following induction
The vector may have the wrong
promoter or there may be a cloning
design problem.
dot Ensure that the promoter is compatible with
the T7 RNA polymerase-based expression
systems.
dot Ensure that the gene of interest has an
initiation codon or it is in the correct frame
with the fusion tag and stop elements.
Sequence the construct to ensure that no
undesired changes have been introduced
during the cloning steps.
You may not have added any or
enough IPTG to induce protein
expression.
Check the induction requirements for your vector.
The protein does not express
well in E. coli.
Use a different expression system.
Top of PageTop of Page
OBSERVATION
POSSIBLE CAUSE
RECOMMENDATIONS
Insoluble protein Temperature, IPTG concentration,
fusion tags and denaturing conditions
can affect solubility.
dot Lower the temperature during induction.
dot Lower the IPTG concentration.
dot Use a different fusion tag.
dot Use denaturing conditions to solubilize the
protein.
Top of PageTop of Page
Related Products

Available Strains:

Related Products:

Additional Resources

Frequently Asked QuestionsPDF symbol

Trouble Shooting Guides Trouble Shooting Guide

Diagrams and Protocols

PDF symbolDownload Acella™ Brochure

Get Adobe Acrobat Reader for PDFsGet Adobe Acrobat Reader for PDFs

 

Home | Site Map | Search

 
Edge BioSystems | 201 Perry Parkway, Suite 5 | Gaithersburg, MD 20877 | 800-326-2685
Copyright © Edge BioSystems, All rights reserved.